On This Page On This Page PURCHASE WITH CONFIDENCE Discover the 17 questions you need to ask before buying your next autoclave. Get the Guide Lab Ventilation Systems for Your Autoclave Written by: Scott Mechler BS Mechanical Engineering, Mechanical Engineer The need for a proper lab ventilation system when running a sterilization cycle in your laboratory autoclave cannot be understated. Ventilation for autoclaves assures that the various odors, steam moisture and low-levels of chemical vapors that come from the sterilization process do not escape further into the laboratory setting. When not regulated correctly with an adequate lab ventilation system, these vapors can pose serious health and safety concerns for lab personnel. Dangerous consequences of faulty ventilation for autoclaves Take for example a recent incident involving several staff and students at Massey University’s Albany campus in New Zealand. After complaining of sore throats, headaches, nausea and itchy eyes, it was discovered that the faculty and students had been exposed to fumes that had incorrectly vented into a student center. Further investigation into the unexplained symptoms found that days earlier the affected staff and students had been exposed to formaldehyde when a container of embalmed pig carcasses was opened without being properly cleaned first. Ultimately it was concluded that the smell was caused by material from an autoclave used in the science building to dispose of biological material. The unpleasant odor, as it turns out had inadvertently been ventilated into the student center. At the conclusion of the investigation it was determined that the school’s ventilation standards had been subpar for quite some time. The importance of lab ventilation systems As you can see by the above example, ventilation for autoclaves is a critically important element to the sterilization process. Your autoclave, which is essentially a giant steam oven, has the potential to expel unwanted exhaust at various points in a cycle—whether it’s during the sterilization process when steam is being condensed down to water through an exhaust line, or once you’ve opened the chamber door after your cycle has finished. Large autoclaves used to sterilize liquid loads can produce a billow or cloud of vapor, and without a functionally adequate lab ventilation system, that vapor can escape and do some serious harm to you or your surroundings—especially if your autoclave is situated in a small room. Other unintended consequences include: False smoke alarms Triggering low-temp sprinkler heads General discomfort Structural building concerns (i.e. weakened drop ceilings) The most critical of consequences involves the health and safety of your laboratory personnel. As evidenced in the above story, the sterilization of something like formaldehyde can create noxious fumes, which can lead to dangerous if not downright fatal consequences. It’s never a good idea to sterilize any liquid capable of producing a noxious fume without a functioning ventilation system. The proper safety personnel should always be involved when sterilizing something outside of your standard operating procedure. Solutions Lab ventilation systems come in all shapes and sizes—some come in the form of a canopy exhaust hood situated over the autoclave, while others are positioned directly over the door of the autoclave itself. The most common type of ventilation system involves a fan or intake system that uses forced air to draw all moisture and vapor into the hood. Another solution is to construct a large canopy hood without a fan above the autoclave that allows any steam or vapor from the chamber to flow directly into it and out of the room. It is recommended that the canopy hood be directly connected to exhaust ductwork. Other recommendations include: Doors to your autoclave rooms should be kept closed. Autoclave door should not be opened too soon after a run is finished. Crack the door initially to let out majority of steam. Fully open slowly to enhance capture of steam. Once the door has been opened, the operator should allow several minutes for the steam and odors to escape and the load to cool somewhat prior to removing contents from the autoclave. Do not discard liquid from bag down sink if this will create odors. Please contact us with any inquires or if you would like more information on lab ventilation systems. 17 Questions to Ask Before Buying Your Next Autoclave With so many models, sizes, options and components to choose from, how can you ever really know exactly what you need to make the most out of your investment? These questions will help you to make informed decisions by outlining what is most important to consider and know about owning an autoclave. First Name* Last Name* Company/Organization* Email* Job Title*Select OneArchitectGeneral ContractorLab ManagerFacilities ManagerService TechnicianScientistSterile Processing TechnicianDistributorOtherDescribe "Other"* Country*AfghanistanAlbaniaAlgeriaAmerican SamoaAndorraAngolaAntigua and BarbudaArgentinaArmeniaAustraliaAustriaAzerbaijanBahamasBahrainBangladeshBarbadosBelarusBelgiumBelizeBeninBermudaBhutanBoliviaBosnia and HerzegovinaBotswanaBrazilBruneiBulgariaBurkina FasoBurundiCambodiaCameroonCanadaCape VerdeCayman IslandsCentral African RepublicChadChileChinaColombiaComorosCongo, Democratic Republic of theCongo, Republic of theCosta RicaCôte d'IvoireCroatiaCubaCuraçaoCyprusCzech RepublicDenmarkDjiboutiDominicaDominican RepublicEast TimorEcuadorEgyptEl SalvadorEquatorial GuineaEritreaEstoniaEthiopiaFaroe IslandsFijiFinlandFranceFrench PolynesiaGabonGambiaGeorgiaGermanyGhanaGreeceGreenlandGrenadaGuamGuatemalaGuineaGuinea-BissauGuyanaHaitiHondurasHong KongHungaryIcelandIndiaIndonesiaIranIraqIrelandIsraelItalyJamaicaJapanJordanKazakhstanKenyaKiribatiNorth KoreaSouth KoreaKosovoKuwaitKyrgyzstanLaosLatviaLebanonLesothoLiberiaLibyaLiechtensteinLithuaniaLuxembourgMacedoniaMadagascarMalawiMalaysiaMaldivesMaliMaltaMarshall IslandsMauritaniaMauritiusMexicoMicronesiaMoldovaMonacoMongoliaMontenegroMoroccoMozambiqueMyanmarNamibiaNauruNepalNetherlandsNew ZealandNicaraguaNigerNigeriaNorthern Mariana IslandsNorwayOmanPakistanPalauPalestine, State ofPanamaPapua New GuineaParaguayPeruPhilippinesPolandPortugalPuerto RicoQatarRomaniaRussiaRwandaSaint Kitts and NevisSaint LuciaSaint Vincent and the GrenadinesSamoaSan MarinoSao Tome and PrincipeSaudi ArabiaSenegalSerbiaSeychellesSierra LeoneSingaporeSint MaartenSlovakiaSloveniaSolomon IslandsSomaliaSouth AfricaSpainSri LankaSudanSudan, SouthSurinameSwazilandSwedenSwitzerlandSyriaTaiwanTajikistanTanzaniaThailandTogoTongaTrinidad and TobagoTunisiaTurkeyTurkmenistanTuvaluUgandaUkraineUnited Arab EmiratesUnited KingdomUnited StatesUruguayUzbekistanVanuatuVatican CityVenezuelaVietnamVirgin Islands, BritishVirgin Islands, U.S.YemenZambiaZimbabweState*Select OneAlabamaAlaskaArizonaArkansasCaliforniaColoradoConnecticutDelawareFloridaGeorgiaHawaiiIdahoIllinoisIndianaIowaKansasKentuckyLouisianaMaineMarylandMassachusettsMichiganMinnesotaMississippiMissouriMontanaNebraskaNevadaNew HampshireNew JerseyNew MexicoNew YorkNorth CarolinaNorth DakotaOhioOklahomaOregonPennsylvaniaRhode IslandSouth CarolinaSouth DakotaTennesseeTexasUtahVermontVirginiaWashingtonWest VirginiaWisconsinWyomingAre You Looking to Purchase an Autoclave?*Select OneYes, ImmediatelyYes, within 6 monthsYes, later than 6 monthsNo, just researchingAre you in a medical/healthcare (patient use) or life science (laboratory) setting?*Select OneMedical/HealthcareLife Science Yes, I'd like to receive occasional tips on sterilization best practices. Comments (Optional)This field is for validation purposes and should be left unchanged. Δ Tweet Like Share
Lab Ventilation Systems for Your Autoclave Written by: Scott Mechler BS Mechanical Engineering, Mechanical Engineer The need for a proper lab ventilation system when running a sterilization cycle in your laboratory autoclave cannot be understated. Ventilation for autoclaves assures that the various odors, steam moisture and low-levels of chemical vapors that come from the sterilization process do not escape further into the laboratory setting. When not regulated correctly with an adequate lab ventilation system, these vapors can pose serious health and safety concerns for lab personnel. Dangerous consequences of faulty ventilation for autoclaves Take for example a recent incident involving several staff and students at Massey University’s Albany campus in New Zealand. After complaining of sore throats, headaches, nausea and itchy eyes, it was discovered that the faculty and students had been exposed to fumes that had incorrectly vented into a student center. Further investigation into the unexplained symptoms found that days earlier the affected staff and students had been exposed to formaldehyde when a container of embalmed pig carcasses was opened without being properly cleaned first. Ultimately it was concluded that the smell was caused by material from an autoclave used in the science building to dispose of biological material. The unpleasant odor, as it turns out had inadvertently been ventilated into the student center. At the conclusion of the investigation it was determined that the school’s ventilation standards had been subpar for quite some time. The importance of lab ventilation systems As you can see by the above example, ventilation for autoclaves is a critically important element to the sterilization process. Your autoclave, which is essentially a giant steam oven, has the potential to expel unwanted exhaust at various points in a cycle—whether it’s during the sterilization process when steam is being condensed down to water through an exhaust line, or once you’ve opened the chamber door after your cycle has finished. Large autoclaves used to sterilize liquid loads can produce a billow or cloud of vapor, and without a functionally adequate lab ventilation system, that vapor can escape and do some serious harm to you or your surroundings—especially if your autoclave is situated in a small room. Other unintended consequences include: False smoke alarms Triggering low-temp sprinkler heads General discomfort Structural building concerns (i.e. weakened drop ceilings) The most critical of consequences involves the health and safety of your laboratory personnel. As evidenced in the above story, the sterilization of something like formaldehyde can create noxious fumes, which can lead to dangerous if not downright fatal consequences. It’s never a good idea to sterilize any liquid capable of producing a noxious fume without a functioning ventilation system. The proper safety personnel should always be involved when sterilizing something outside of your standard operating procedure. Solutions Lab ventilation systems come in all shapes and sizes—some come in the form of a canopy exhaust hood situated over the autoclave, while others are positioned directly over the door of the autoclave itself. The most common type of ventilation system involves a fan or intake system that uses forced air to draw all moisture and vapor into the hood. Another solution is to construct a large canopy hood without a fan above the autoclave that allows any steam or vapor from the chamber to flow directly into it and out of the room. It is recommended that the canopy hood be directly connected to exhaust ductwork. Other recommendations include: Doors to your autoclave rooms should be kept closed. Autoclave door should not be opened too soon after a run is finished. Crack the door initially to let out majority of steam. Fully open slowly to enhance capture of steam. Once the door has been opened, the operator should allow several minutes for the steam and odors to escape and the load to cool somewhat prior to removing contents from the autoclave. Do not discard liquid from bag down sink if this will create odors. Please contact us with any inquires or if you would like more information on lab ventilation systems. 17 Questions to Ask Before Buying Your Next Autoclave With so many models, sizes, options and components to choose from, how can you ever really know exactly what you need to make the most out of your investment? These questions will help you to make informed decisions by outlining what is most important to consider and know about owning an autoclave. First Name* Last Name* Company/Organization* Email* Job Title*Select OneArchitectGeneral ContractorLab ManagerFacilities ManagerService TechnicianScientistSterile Processing TechnicianDistributorOtherDescribe "Other"* Country*AfghanistanAlbaniaAlgeriaAmerican SamoaAndorraAngolaAntigua and BarbudaArgentinaArmeniaAustraliaAustriaAzerbaijanBahamasBahrainBangladeshBarbadosBelarusBelgiumBelizeBeninBermudaBhutanBoliviaBosnia and HerzegovinaBotswanaBrazilBruneiBulgariaBurkina FasoBurundiCambodiaCameroonCanadaCape VerdeCayman IslandsCentral African RepublicChadChileChinaColombiaComorosCongo, Democratic Republic of theCongo, Republic of theCosta RicaCôte d'IvoireCroatiaCubaCuraçaoCyprusCzech RepublicDenmarkDjiboutiDominicaDominican RepublicEast TimorEcuadorEgyptEl SalvadorEquatorial GuineaEritreaEstoniaEthiopiaFaroe IslandsFijiFinlandFranceFrench PolynesiaGabonGambiaGeorgiaGermanyGhanaGreeceGreenlandGrenadaGuamGuatemalaGuineaGuinea-BissauGuyanaHaitiHondurasHong KongHungaryIcelandIndiaIndonesiaIranIraqIrelandIsraelItalyJamaicaJapanJordanKazakhstanKenyaKiribatiNorth KoreaSouth KoreaKosovoKuwaitKyrgyzstanLaosLatviaLebanonLesothoLiberiaLibyaLiechtensteinLithuaniaLuxembourgMacedoniaMadagascarMalawiMalaysiaMaldivesMaliMaltaMarshall IslandsMauritaniaMauritiusMexicoMicronesiaMoldovaMonacoMongoliaMontenegroMoroccoMozambiqueMyanmarNamibiaNauruNepalNetherlandsNew ZealandNicaraguaNigerNigeriaNorthern Mariana IslandsNorwayOmanPakistanPalauPalestine, State ofPanamaPapua New GuineaParaguayPeruPhilippinesPolandPortugalPuerto RicoQatarRomaniaRussiaRwandaSaint Kitts and NevisSaint LuciaSaint Vincent and the GrenadinesSamoaSan MarinoSao Tome and PrincipeSaudi ArabiaSenegalSerbiaSeychellesSierra LeoneSingaporeSint MaartenSlovakiaSloveniaSolomon IslandsSomaliaSouth AfricaSpainSri LankaSudanSudan, SouthSurinameSwazilandSwedenSwitzerlandSyriaTaiwanTajikistanTanzaniaThailandTogoTongaTrinidad and TobagoTunisiaTurkeyTurkmenistanTuvaluUgandaUkraineUnited Arab EmiratesUnited KingdomUnited StatesUruguayUzbekistanVanuatuVatican CityVenezuelaVietnamVirgin Islands, BritishVirgin Islands, U.S.YemenZambiaZimbabweState*Select OneAlabamaAlaskaArizonaArkansasCaliforniaColoradoConnecticutDelawareFloridaGeorgiaHawaiiIdahoIllinoisIndianaIowaKansasKentuckyLouisianaMaineMarylandMassachusettsMichiganMinnesotaMississippiMissouriMontanaNebraskaNevadaNew HampshireNew JerseyNew MexicoNew YorkNorth CarolinaNorth DakotaOhioOklahomaOregonPennsylvaniaRhode IslandSouth CarolinaSouth DakotaTennesseeTexasUtahVermontVirginiaWashingtonWest VirginiaWisconsinWyomingAre You Looking to Purchase an Autoclave?*Select OneYes, ImmediatelyYes, within 6 monthsYes, later than 6 monthsNo, just researchingAre you in a medical/healthcare (patient use) or life science (laboratory) setting?*Select OneMedical/HealthcareLife Science Yes, I'd like to receive occasional tips on sterilization best practices. Comments (Optional)This field is for validation purposes and should be left unchanged. Δ Tweet Like Share
7.12.23 Cordyceps Sterilization: How to Kill “The Last of Us” Parasite → In HBO’s recent adaptation of “The Last of Us,” a popular action-adventure video game, life as we know it is upended by a parasitic fungus that transforms its human hosts into zombies. The culprit? Cordyceps, a real-life genus of fungus which is best known for infecting insects (most famously ants) in much the same manner […]
6.30.23 Top 13 Sterile Processing Mistakes in Hospitals → When it comes to ensuring patient safety in hospitals and ambulatory surgery centers (ASCs), the Sterile Processing Department (SPD) is among the last lines of defense. It’s this department’s sole responsibility to make sure that reusable instruments and devices are properly decontaminated, sterilized, and ultimately safe to use in future procedures — protecting patients from […]
6.22.23 Sterilization vs. High-Level and Low-Level Disinfection [a 3-Point Comparison] → In a 1939 paper, microbiologist Earle H. Spaulding introduced a system for determining which medical devices and instruments needed disinfection and which ones required sterilization. In it, he proposed that critical instruments would need to be subjected to more stringent disinfection protocols than non-critical patient care items. Today, this framework is fittingly known as Spaulding […]